OFT-820-POF series Plastic optical fiber - Loss Test Set
The OFT-820N-POF series Loss Test Set is designed for POF – Plastic Optical Fiber network testing. It combines two optical test equipment – a Light Source and a Power Meter in the same box. The tester can be used as a portable power meter or as a USB probe, part of a testing workstation. The optical Light Source fulfils all the necessary technical requirements for field POF network measurements. The source sends optical light into the output interface, available in working wavelengths 650 nm and 850 nm at separate OUT ports. The optical Power Meter is designed to measure absolute or relative optical power in POF networks.
The memory capacity allows storage and uploading of up to 3000 measurements including memory position or fibre number, wavelength, absolute value or relative value and insertion loss. The rechargeable battery ensures long-term working with a minimum lifetime of 2 years.
The removable and changeable IN/OUT adapters allow easy maintenance and cleaning of both ports, making the tester universal in a wide range of applications with various POF connectors. The design of both input and output adapters is the same.
- Three sets of standard IN/OUT adapters: 2x LS, 1x PM
- Power charging adaptor
- USB-C connection cable
- Hard carrying case, TE-HC-03, 265x270x90 mm
- Calibration certificate
- Options: SMA adapters
- Two functions: Portable power meter & USB probe – accessory of Testing Workplace, full control via simple commands
- POF testing
- Small size, light weight
- Easy exchangeable adapters – source and power meter:
- Set of POF adapters: HFBR, universal 2.5 mm ferrule and universal 2.2 mm POF cable, SMA
- High capacity memory
- Absolute and Relative optical power measurement
- Displayed units: dBm, dB, W
- Powered by built-in rechargeable battery
- Contrast display with backlight
- Battery status indicator, Auto Off function
Power Meter |
Note: |
||
Photodetector |
3 mm Si |
|
|
Working wavelengths |
650 nm, 850 nm |
can be customized |
|
Uncertainty |
± 5% |
|
|
Resolution |
0.01 |
|
|
Dynamic range |
-65 dBm to +10 dBm |
650 nm, 850 nm |
|
Light Source |
|||
Wavelength |
650 nm, 850 nm |
||
Output power |
0 dBm |
|
|
Stability (1 hour, delta/2): |
± 0.03 dB |
tested after 20 min warm up temperature 23 ± 1° |
|
Loss Test Set |
|||
Dimensions |
165 x 80 x 50 mm |
with universal adapter |
|
Weight |
350 g |
with battery |
|
Temperature operating storage Humidity (non condensing) |
-10 to +50 °C -40 to +70 °C 0 – 95% |
|
|
Battery working time |
> 80 hrs |
backlight off |
|
Battery life time |
> 2 years |
3000 mAh LiPol |
Compliant with RoHS-requirements (2002/95/EG, 27.01.2003)
Standard: | Options: | ||
TE-APF-HFBR | TE-APF-250 | TE-APF-220 | TE-APF-SMA |
OFT-820N-POF
Loss test Set, 650+850 nm working wavelengths, 3 sets of standard POF IN/OUT adapters
Power meter control from PC:
Download the SW PM215E application from:
https://www.optokon.com/clanek/37-stazeni-manualu-a-ovladacu-pro-merici-pristroje