SFT-TAP Test Access Point splitter
The OPTOKON SFT-TAP splitter is designed for optical network monitoring during operation. According to the operatotor request it allows bi-directional or uni-directional monitoring of optical fiber in full CWDM wavelength range. The splitting ratio of TAP port can be customized in 1% – 50% rate. Wide range of the packaging types allows easy implementation into optical network which would be monitored. The SFT-TAP splitter can be installed directly into the system of optical distribution frames or delivered separately in boxes according to the operator demand.
- Passive access to fiber optic network
- Protocol and transmission speed independent
- High port isolation
- Custom defined specifications
- Environmentally stable
- Wavelength independent - full CWDM spectrum
- Up to 16 TAP modules in 1U rack mount cconfiguration
ITEM |
Test Access Point splitter |
Operating Wavelength, nm |
1270 – 1630 (CWDM wavelength range) |
Thermal Stability, dB (peak-peak) |
< 0.2 |
PDL, dB |
< 0.15, PDL free (< 0.05) – on request |
Port Configuration |
2 x 2 or 2 x 1 |
Coupling Ratio |
1:99 to 10:90, (on request other) |
Insertion Loss1), dB |
Refer to the coupling ratio vs. Insertion loss chart |
Directivity, dB |
> 50 |
Return Loss, dB |
> 50 |
Operating Temperature2), °C |
-40 to +85 |
Storage Temperature2), °C |
-50 to +85 |
WARNING |
This product should never be installed in an optical |
Note: 1) Without connectors
2) Conditioned by the cable type
Block diagram:
Coupling Ratio vs. Insertion Loss: AT |
|
Coupling Ratio (%) |
Insertion Loss (dB) |
1 /99 |
24.3 / 0.2 |
10 / 90 |
12.0 / 0.7 |
30 / 70 |
6.2 / 1.9 |
50 / 50 |
3.6 |
Packaging variants:
|
SFT-TAP-AT-10-CM1-NC |
|
SFT-TAP-D-10-CAPM-ULCD |
TAP-D configuration
Internal connection |
Front panel marking |
SFT-6xTAP-D-30-ZMPJ-NLC |
SFT |
- |
TAP |
- |
XXXX |
- |
XX |
- |
XXX |
- |
NC |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Type |
Wavelength |
|
TAP ports |
|
|
|
No input and output connectors3) |
|||||||||||
TAP1) |
1270 - 1630 nm |
|
AT |
|
|
|
Connector type - according to CON_14-01 |
|||||||||||
|
|
|
D duplex AT |
|
|
|
|
(Jumper Ordering Code) |
||||||||||
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
Package option I |
|||||||||||
|
|
|
|
|
|
|
FM1 |
Fiber type, metal box 100x15x9 mm |
||||||||||
Note: |
Coupling ratio |
|
CM1 |
Cable type, metal box 100x15x9 mm |
||||||||||||||
1) ±0.3 dB typ. tolerance A↔B |
01 |
1/99 |
|
FM3 |
Fiber type, metal box 100x80x10, stackable |
|||||||||||||
(1370, 1390, 1410 nm IL increased for 0.2-0.3 dB) |
10 |
10/90 |
|
CM3 |
Cable type, metal box 100x80x10, stackable |
|||||||||||||
2) Optional according to requirements |
30 |
30/70 |
|
|
||||||||||||||
3) Standard fiber/cable length = 1 m |
50 |
50/50 |
|
Package option II |
||||||||||||||
|
Other2) |
|
XXX : Part number of relevant ODF (e.g. MCNP, TMVJ, ZMPJ) |
|||||||||||||||
|
|
|
|
CAPM |
OPTOKON cassette |
|||||||||||||
|
|
|
MPIC |
Wall mount MPIC unit |