Outdoor Multi-tube Micro Cable 36F (3RD)
Outdoor Multi-tube Micro Cable 36F (3RD)
Rev. 0275-22/22
Cable for external installation by air-blowing technique
Fiber Type |
G.657.A1 200µm |
Fiber color |
Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua |
Tube |
Gel-Filled PBT buffer tube |
Tube color |
Blue, Orange, Green, |
Tube filling compound |
Low-viscosity filling compound |
Strength member |
Aramid yarn |
Core filling compound |
Low-viscosity filling compound |
Outer jacket |
Low Friction Plastic |
Outer jacket thickness |
0.4 mm |
Cable outer diameter |
3.4 |
[mm] |
|
Max. Loading (Short Term) |
70 |
[N] |
EN 60794-1-21-E1 |
Max. Loading (Long Term) |
20 |
[N] |
EN 60794-1-21-E1 |
Max. compressive loading |
500 |
[N/10cm] |
EN 60794-1-21-E3 |
Max. Impact loading |
3 |
[Nm] |
EN 60794-1-21-E4 |
Min. bend radius not load |
50 |
[mm] |
EN 60794-1-21-E11 |
Min. bend radius load |
65 |
[mm] |
EN 60794-1-21-E11 |
Operating temperature range |
-30 to +70 |
[°C] |
EN 60794-1-22-F1 |
Storage temperature range |
-40 to +70 |
[°C] |
EN 60794-1-22-F1 |
Installation temperature range |
-10 to +50 |
[°C] |
EN 60794-1-22-F1 |
Cable Weight (calc.) |
11 |
[kg/km] |
|
Class of fire reaction |
Fca |
|
EN 13501-6 |
Attenuation @Wavelength 1310 / 1550 / 1625 [nm]
Typical Attenuation 0.33 / 0.23 / 0.24 [dB/km]
Maximum Attenuation 0.38 / 0.28 / 0.35 [dB/km]
Typical attenuation is the value measured for at least 90% of the fibers in the cable.
OPK-O-MTFFM-36(3x1.2)LTAB-200A1-xx
xx – jacket color (see Cable code datasheet)
Print legend OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length 2100 m, 4200 m, 6300 m ±5% on plywood reel