Air Blown Unit 2.4
Air Blown Unit 2.4
Rev. 0258-22/13
Lightweight cable with a hard and smooth surface, suitable for installation by blowing technique.
Fiber count |
24 |
Fiber Type |
G.657.A1 200 μm |
Fiber colour |
1-12 Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua |
|
13-24 BlueBS, OrangeBS, GreenBS, BrownBS, GreyBS, WhiteBS, RedBS, Natural, |
Filling compound |
Low-viscosity filling compound |
Cable colour |
Orange |
Cable outer diameter |
2.4±0.1 |
[mm] |
|
Max. Tensile Loading (Short Term) |
45 |
[N] |
EN 60794-1-21-E1 |
Max. Tensile Loading (Long Term) |
10 |
[N] |
EN 60794-1-21-E1 |
Max. compressive loading |
100 |
[N/10cm] |
EN 60794-1-21-E3 |
Min. bend radius |
30 |
[mm] |
EN 60794-1-21-E11 |
Operating temperature range |
-20 to +70 |
[°C] |
EN 60794-1-22-F1 |
Storage temperature range |
-20 to +70 |
[°C] |
EN 60794-1-22-F1 |
Installation temperature range |
+5 to +50 |
[°C] |
EN 60794-1-22-F1 |
Water tightness |
No water detected on free end |
|
EN 60794-1-22-F5 |
Cable Weight (calc.) |
5.8 |
[kg/km] |
|
Class of fire reaction |
Fca |
|
EN 13501-6 |
Fiber count |
Cable Code (Ordering Code) |
24 |
OPK-O-CTFB-24(1x2.4)LTB-200A1-OG |
Print legend: OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m ±5% on plywood reel