OPTOKON

Universal Multitube Cable 144F (NC) with Kevlar

Universal Multitube Cable 144F (NC) with Kevlar

Universal Multitube Cable 144F (NC) with Kevlar
Rev. 0072-21/03

Fiber optic cable for indoor or outdoor installation onto grids or into ducts by pulling

Fiber count

144

Fiber Type

G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM3, OM4, OM5

Fiber colour

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube colour

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Filling compound

Low-viscosity filling gel

Strength member

FRP rod, PE coated

Core wrapping

Water-swellable tape

Peripheral strength members

Water-swellable kevlar yarns

Ripcord

1x under outer jacket

Outer jacket

UV resistant Black Thermoplastic Flame Retardant Low Smoke Halogen Free compound according
to BS 7878:7  and  DIN VDE 0207, part 24, type HM2

Jacket thickness

1.5 mm

 

Cable outer diameter

12.0

[mm]

 

Tube count

12

 

 

Filler count

0

 

 

Maximum tensile loading (Short Term)

5500

[N]

EN 60794-1-21-E1

Maximum tensile loading (Long Term)

2000

[N]

EN 60794-1-21-E1

Max. compressive loading

2000

[N/10cm]

EN 60794-1-21-E3

Max. Impact loading

10

[Nm ]

EN 60794-1-21-E4

Min. bend radius (no load)

15

[OD]

EN 60794-1-21-E11

Operating temperature range

-40 to +70

[°C]

EN 60794-1-22-F1

Storage temperature range

-40 to +70

[°C]

EN 60794-1-22-F1

Installation temperature range

-15 to +50

[°C]

EN 60794-1-22-F1

Water tightness

No water detected on free end

 

EN 60794-1-22-F5

Cable Weight (calc.)

139

[kg/km]

 

Class of fire reaction

Fca

 

EN 13501-6

 

OPK-U-MTFDS-144(12x1.7)LTAH-xx-BK
xx – fiber type (see Cable code datasheet) 

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2000 m, 4000 m ±5% on plywood reel or solid wooden non-returnable drum