OPTOKON

Outdoor Multitube Cable 72F (NC)

Outdoor Multitube Cable 72F (NC)

Outdoor Multitube Cable 72F (NC)
Rev. 0032-21/35

Full dielectric cable for external installation on cable trays or into duct by pulling

Fiber count

72

Fiber Type

G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM2+, OM3, OM4

Fiber color

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube color

Blue, Orange, Green, Brown, Grey, White

Tube filling compound

Low-viscosity filling gel

Central strength member

FRP rod

Core wrapping

Water-swellable tape

Peripheral strength members

Water-swellable glass yarns

Ripcord

1x under outer jacket

Outer jacket

UV resistant black HDPE

Jacket thickness

1.1 mm

Cable outer diameter

8.1

[mm]

 

Tube count

6

 

 

Filler count

0

 

 

Max. Tensile Loading (Short Term)

1900

[N]

EN 60794-1-21-E1

Max. Tensile Loading (Long Term)

500

[N]

EN 60794-1-21-E1

Max. compressive loading

2000

[N]

EN 60794-1-21-E3

Max. Impact loading

10

[Nm]

EN 60794-1-21-E4

Min. bend radius (no load)

15

[OD]

EN 60794-1-21-E11

Min. bend radius (maximum load)

20

[OD]

EN 60794-1-21-E11

Operating temperature range

-40 to +70

[°C]

EN 60794-1-22-F1

Storage temperature range

-40 to +70

[°C]

EN 60794-1-22-F1

Installation temperature range

-15 to +50

[°C]

EN 60794-1-22-F1

Water tightness

No water detected on free end

 

EN 60794-1-22-F5

Cable Weight (calc.)

56

[kg/km]

 

Class of fire reaction

Fca

 

EN 13501-6

 

OPK-O-MTFDS-72(6x1.7)LTGP-xx-BK
xx – fiber type (see Cable code datasheet) 

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m, 4200 m ±5% on plywood reel or solid wooden non-returnable drum