OPTOKON

Outdoor Multitube Cable 288F (HC)

Outdoor Multitube Cable 288F (HC)

Outdoor Multitube Cable 288F (HC)
Rev. 0130-20/23

Full dielectric cable for external installation on cable trays or into duct by pulling.

Fiber count

288

Fiber Type

G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM2+, OM3, OM4

Fiber color

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube color – inner layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow

Tube color – outer layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua,
BlueBS, OrangeBS, GreenBS    (BS  Black strip)

Tube filling compound

Thixotropic Jelly Compound

Central strength member

PE coated FRP rod

Core wrapping

Water-swellable tape

Peripheral strength members

Water-swellable glass yarns

Ripcord

1x under outer jacket

Outer jacket

UV resistant black HDPE

Jacket thickness

1.5 mm

 

Cable outer diameter

17.6

[mm]

Tube count

18 (9+15)

 

Filler count

0

 

Max. Loading (Short Term)

5700

[N]

Max. Loading (Long Term)

2600

[N]

Max. compressive loading

2000

[N]

Max. Impact loading

20

[Nm ]

Min. bend radius not load

15

[OD]

Min. bend radius load

20

[OD]

Operating temperature range

-40 to +70

[°C]

Storage temperature range

-40 to +70

[°C]

Installation temperature range

-15 to +50

[°C]

Cable Weight (calc.)

239

[kg/km]

Class of fire reaction

Fca

 

Test standards: EN 60790-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6

 

OPK-O-MTFDS-288(24x2.3)LTGP-xx-BK
xx – fiber type (see Cable code datasheet) 

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m ±5% on plywood reel or solid wooden non-returnable drum