OPTOKON

Universal Multitube Cable 288F (HC)

Universal Multitube Cable 288F (HC)

Universal Multitube Cable 288F (HC)
Rev. 0140-20/23

Full dielectric cable for external or internal installation on cable trays or into duct by pulling.

Fiber count

288

Fiber Type

G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM2+, OM3, OM4, OM5

Fiber color

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube color – inner layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow

Tube color – outer layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink,
Aqua, BlueBS, OrangeBS, GreenBS    (BS  Black strip)

Tube filling compound

Thixotropic Jelly Compound

Central strength member

PE coated FRP rod

Core wrapping

Water-swellable tape

Peripheral strength members

Water-swellable glass yarns

Ripcord

1x under outer jacket

Outer jacket

UV resistant Thermoplastic FR-LSHF compound according to BS 7878:7
and  DIN VDE 0207, part 24, type HM2

Jacket thickness

2.0 mm

 

Cable outer diameter

18.7

[mm]

Tube count

18 (9+15)

 

Filler count

0

 

Max. Loading (Short Term)

5700

[N]

Max. Loading (Long Term)

2600

[N]

Max. compressive loading

2000

[N]

Max. Impact loading

20

[Nm ]

Min. bend radius not load

15

[OD]

Min. bend radius load

20

[OD]

Operating temperature range

-40 to +70

[°C]

Storage temperature range

-40 to +70

[°C]

Installation temperature range

-15 to +50

[°C]

Cable Weight (calc.)

318

[kg/km]

Class of fire reaction

Fca

 

 Test standards: EN 60790-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6 

 

OPK-U-MTFDS-288(24x2.3)LTGH-xx-yy
xx – fiber type, yy – jacket colour (see Cable code datasheet) 

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m ±5% on plywood reel or solid wooden non-returnable drum