Highly durable flexible cable for applications where there is a requirement for data communication by fiber optic and at the same time is needed power supply. Suitable for FTTA applications, CCTV systems or for connections of movable equipment.
 

Fibre count

2

Fibre Type

G.657.A1, G.657.A2

Fibre colour

Natural

Buffer diameter

0.9 mm

Buffer material

UV curable acrylate

Buffer colour

Blue

Simplex Colour

Yellow (identified by numbers #1 a #2)

Simplex jacket

Halogen-free flame-retardant thermoplastic compound

Simplex diameter

1.8 mm

Conductor count

3

Conductor

Stranded Tinned Copper, AWG 16 (19x0.3 mm)

Wire Insulation material

FEP

Wire Insulation colour

White, Black, Red

Wire Insulation diameter

1.9 mm

Core wrapping

Water-swellable tape

Strength members

Water-swellable Aramid yarns

Inner jacket

Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)

Inner jacket thickness

0.8 mm

Peripheral strength members Water-swellable glass yarns

 

Outer jacket

UV stable Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)

Outer jacket thickness

1.3 mm

 

Cable outer diameter

11.7 mm

 

Max. Loading (Short Term)

8000 N

EN 60794-1-21-E1

Max. Loading (Long Term)

3500 N

EN 60794-1-21-E1

Abrasion

5N/10 000 cycles

EN 60794-1-21-E2

Max. compressive loading

5500 N/10cm]

EN 60794-1-21-E3

Max. Impact loading

27 Nm

EN 60794-1-21-E4

Kink

150 mm

EN 60794-1-21-E10

Min. bend radius not load

75 mm

EN 60794-1-21-E11

Min. bend radius load

150 mm

EN 60794-1-21-E11

Torsion resistence

±360°

EN 60794-1-21-E7

Wire resistance

14.6 Ohm/km at 20°C

 

Wire Insulation Spark Test 3000V/0.15 sec.

Pass

 

Test voltage underwater 2000V/ 1 hour (room temp.)

Pass

 

Operating temperature range (static)

-40 až +70°C

EN 60794-1-22-F1

Operating temperature range (dynamic)

-10 až +70°C

EN 60794-1-22-F1

Storage temperature range

-40 až +70°C

EN 60794-1-22-F1

Freezing test

Pass

IEC 60794-1-22-F15

Aging test

Pass

IEC 60794-1-22-F9

Water tightness

Pass

EN 60794-1-22-F5

Cable Weight (calc.)

66 kg/km

 

Class of fire reaction

Fca

EN 13501-6

Static coefficient of friction (stainless steel - dry)

0.73

 

 

OPK-U-SPC-2(5×1,8)A9AEUGU-xx-BK
xx – fiber type (see Cable code datasheet) 

Print legend: Manufacturer –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length            2100 m±5% on plywood reel or solid wooden non-returnable drum