OPTOKON

Outdoor Multitube Micro Cable 432F (NC)

Outdoor Multitube Micro Cable 432F (NC)

Outdoor Multitube Micro Cable 432F (NC)
Rev. 0173-20/17

Cable for external installation by air-blowing technique.

Fiber count

432

Fiber Type

G.657.A1 200 µm

Fiber color

1-12 Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

13-24 BlueBS, OrangeBS, GreenBS, BrownBS, GreyBS, WhiteBS, RedBS,
Natural, YellowBS, VioletBS, PinkBS, AquaBS     (BS = Black strip)

Tube

Gel-Filled PBT buffer tube

Tube color – inner layer

Blue, Orange, Green, Brown, Grey, White

Tube color – outer layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube filling compound

Thixotropic Jelly Compound

Central strength member

FRP rod

Ripcord

1x under outer jacket

Outer jacket

UV resistant black HDPE

Outer jacket thickness

0.45 mm

 

Cable outer diameter

9.5

[mm]

Tube count

18 (6+12

 

Filler count

0

 

Max. Loading (Short Term)

700

[N]

Max. Loading (Long Term)

100

[N]

Max. compressive loading

500

[N]

Max. Impact loading

2

[Nm]

Min. bend radius not load

15

[OD]

Min. bend radius load

20

[OD]

Operating temperature range

-30 to +70

[°C]

Storage temperature range

-40 to +70

[°C]

Installation temperature range

-15 to +50

[°C]

Cable Weight (calc.)

80

[kg/km]

Class of fire reaction

Fca

 

 Test standards: EN 60793-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6 

 

OPK-O-MTFDM-432(18x1,7)LTP-xx-BK
xx – fiber type (see Cable code datasheet)

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m, 4200 m, ±5% on plywood reel or solid wooden non-returnable drum