OPTOKON

Outdoor Multi-tube Micro Cable 192F (CC)

Outdoor Multi-tube Micro Cable 192F (CC)

Outdoor Multi-tube Micro Cable 192F (CC)
Rev. 0049-20/43

Cable for external installation by air-blowing technique.

Fiber count

192

Fiber Type

G.652.D, G.657.A1, G.657.A2, OM1, OM2, OM3, OM4

Fiber color

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube color – inner layer

Blue, Orange, Green, Brown, Grey

Tube color – outer layer

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink

Tube filling compound

Low-viscosity filling compound

Central strength member

FRP rod

Ripcord

1x under outer jacket

Outer jacket

UV resistant black HDPE

Outer jacket thickness

0.5 mm

 

Cable outer diameter

8.3

[mm]

 

Tube count

16 (5+11)

 

 

Filler count

0

 

 

Max. Loading (Short Term)

430

[N]

EN 60794-1-21-E1

Max. Loading (Long Term)

100

[N]

EN 60794-1-21-E1

Max. compressive loading

700

[N/10cm]

EN 60794-1-21-E3

Max. Impact loading

3

[Nm]

EN 60794-1-21-E4

Min. bend radius not load

15

[OD]

EN 60794-1-21-E11

Min. bend radius load

20

[OD]

EN 60794-1-21-E11

Operating temperature range

-30 to +70

[°C]

EN 60794-1-22-F1

Storage temperature range

-40 to +70

[°C]

EN 60794-1-22-F1

Installation temperature range

-15 to +50

[°C]

EN 60794-1-22-F1

Cable Weight (calc.)

59

[kg/km]

 

Class of fire reaction

Fca

 

EN 13501-6

 

OPK-O-MTFDM-192(16x1,5)LTP-xx-BK
xx – fiber type (see Cable code datasheet)

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2100 m, 4200 m, 6300 m ±5% on plywood reel or solid wooden non-returnable drum