Multimode Fiber OM1
Fiber type: 62,5/125 OM1
OPK code: OM1
Rev. 010-21/41
Fiber type |
62.5/125 OM1 |
OPK code |
OM1 |
|
|
Optical Characteristics |
|
Attenuation coefficient Loose Tube Cables (Typical / Maximum) |
|
at 850 nm |
2.6 / 3.5 dB/km |
at 1300 nm |
0.5 / 1.5 dB/km |
Attenuation coefficient Tight Buffered Cables (Typical / Maximum) |
|
at 850 nm |
2.6 / 3.5 dB/km |
at 1300 nm |
0.5 / 1.5 dB/km |
Point of discontinuity at 1300 nm |
≤ 0.2 dB |
Zero dispersion wavelength |
1320 – 1365 nm |
Zero dispersion slope 1320 ≤ l0 ≤ 1348 nm |
≤ 0.11 ps/(nm2·km) |
Zero dispersion slope 1348 ≤ l0 ≤ 1365 nm |
≤ 0.001·(1458-l0 ) ps/(nm2·km) |
Numerical Aperture |
0.275 ± 0.015 |
Effective group index of refraction at 850 nm |
1.497 |
Effective group index of refraction at 1300 nm |
1.493 |
|
|
Performance Characteristics |
|
Bandwidth* (Overfilled launch) |
|
at 850 nm |
≥ 160 – ≥ 250 MHz·km |
at 1300 nm |
≥ 500 – ≥ 800 MHz·km |
Transmission Link Lengths at 1Gb/s1 |
|
at 850 nm |
≥ 300 – ≥ 500 m |
at 1300 nm |
≥ 550 – ≥ 1000 m |
|
|
Geometrical Characteristics |
|
Core diameter |
62.5 ± 2.5 µm |
Core non-circularity |
≤ 5.0 % |
Core/Cladding concentricity error |
≤ 1 µm |
Cladding diameter |
125.0 ± 1.0 µm |
Cladding non-circularity |
≤ 1.0 % |
Primary coating diameter (uncoloured fibre) |
242 ±7 µm |
Primary coating diameter (coloured fibre) |
250 ±10 µm |
Coating-Cladding concentricity |
≤ 10 µm |
|
|
Macrobending loss |
|
100 turns, mandrel diameter 75 mm at 850 nm |
≤ 0.5 dB |
100 turns, mandrel diameter 75 mm at 1300 nm |
≤ 0.5 dB |
|
|
Mechanical Characteristics |
|
Proof test level |
≥ 0.69 Gpa (≥ 8.8 N) |
Coating strip force |
1.9 N |
Dynamic fatigue resistance parameter |
≥ 23 |
|
|
1 for both, bandwidth and link lengths special combinations and values are available. Typical attenuation is the value measured for at least 90% of the fibers in the cable. OTDR measurement values can only be guaranteed for cable lengths of 1000 m and more. Cable on the reel may show an discontinuity of the OTDR curve caused by winding of the cable on the reel.
|